DC Voltage: | |
---|---|
AC Voltage: | |
Output Frequency: | |
Availability: | |
Quantity: | |
TPU-2000W
LCD Digital Display Screen:Using JYINS 2000W inverter charger, user can monitor operating data of applicances in real-time. Let users know the situation of applicance cclearly, which includs: input and output voltage, frequency, battery power, output power wattage, output waveform, inverter working status and other data.
This 2000w inverter charger is especially suitable for connecting devices with high starting currents, such as electric motors, compressors, relays, fluorescent lamps, electric stoves, refrigerators, air conditioners, energy-saving lamps, pumps, etc. The starting power of these devices may be 3 to 7 times the rated power, so only a pure sine wave inverter can meet their needs.
DC input
AC output
AC output
2000W Pure Sine Wave Power Inverter With Battery Charger | ||||
Model | JYPU-2K-1 | JYPU-2K-1 | JYPU-2K-2 | JYPU-2K-2 |
Rated power | 2000W | |||
Peak power | 4000W | |||
Input voltage | DC12V | DC24V | DC12V | DC24V |
Output voltage | 100VAC or 110VAC or 120VAC±5% | 220VAC or 230VAC or 240VAC±5% | ||
Unload current less than | 1.1A | 0.7A | 1.1A | 0.7A |
Output frequency | 50Hz±0.5Hz or 60Hz±0.5Hz | |||
Output waveform | Pure Sine Wave | |||
Waveform distortion | THD<3%(Linear load) | |||
USB port | QC2.0 (5V 2.1A) | |||
Max.efficiency | 90% | |||
Input current | 15A | |||
Input voltage range | 10-15.5V | 20-31V | 10-15.5V | 20-31V |
Low voltage alarm | 10.5±0.5V | 21±0.5V | 10.5±0.5V | 21±0.5V |
Low voltage protection | 10±0.5V | 20±0.5V | 10±0.5V | 20±0.5V |
Over voltage protection | 15.5±0.5V | 31±0.5V | 15.5±0.5V | 31±0.5V |
Low voltage recover | 13±0.5V | 24±0.5V | 13±0.5V | 24±0.5V |
Over voltage recover | 14.8V±0.5V | 29.5V±0.5V | 14.8V±0.5V | 29.5V±0.5V |
Protection function | Low voltage | Alarm at first, voltage continously reduce. LED Red light on & shut sown. | ||
Over voltage | LED Red light on, shut down | |||
Over load | LED Red light on, shut down | |||
Over temperature | Alarm at first, tempurature continously rise.LED Red light on & shut sown | |||
Short circuit | LED Red light on | |||
Input reverse polarity | Fuse burn-out | |||
output current | 15A | 10A | 15A | 10A |
Constant current charging | 15A | 10A | 15A | 10A |
Constant voltage Charging | 14.6VDC | 28.8VDC | 14.6VDC | 28.8VDC |
Floating charge | 13.8VDC | 27.6VDC | 13.8VDC | 27.6VDC |
AC Input voltage Range | 190~260VAC | 90-135VAC | 190~260VAC | 90-135VAC |
Working temperature | -10°- +50° | |||
Storage temperature | -30°- +70° | |||
Note: Our products update constantly.The technical parameter is for reference only.Please refer to our real product. |
Packaging
LCD Digital Display Screen:Using JYINS 2000W inverter charger, user can monitor operating data of applicances in real-time. Let users know the situation of applicance cclearly, which includs: input and output voltage, frequency, battery power, output power wattage, output waveform, inverter working status and other data.
This 2000w inverter charger is especially suitable for connecting devices with high starting currents, such as electric motors, compressors, relays, fluorescent lamps, electric stoves, refrigerators, air conditioners, energy-saving lamps, pumps, etc. The starting power of these devices may be 3 to 7 times the rated power, so only a pure sine wave inverter can meet their needs.
DC input
AC output
AC output
2000W Pure Sine Wave Power Inverter With Battery Charger | ||||
Model | JYPU-2K-1 | JYPU-2K-1 | JYPU-2K-2 | JYPU-2K-2 |
Rated power | 2000W | |||
Peak power | 4000W | |||
Input voltage | DC12V | DC24V | DC12V | DC24V |
Output voltage | 100VAC or 110VAC or 120VAC±5% | 220VAC or 230VAC or 240VAC±5% | ||
Unload current less than | 1.1A | 0.7A | 1.1A | 0.7A |
Output frequency | 50Hz±0.5Hz or 60Hz±0.5Hz | |||
Output waveform | Pure Sine Wave | |||
Waveform distortion | THD<3%(Linear load) | |||
USB port | QC2.0 (5V 2.1A) | |||
Max.efficiency | 90% | |||
Input current | 15A | |||
Input voltage range | 10-15.5V | 20-31V | 10-15.5V | 20-31V |
Low voltage alarm | 10.5±0.5V | 21±0.5V | 10.5±0.5V | 21±0.5V |
Low voltage protection | 10±0.5V | 20±0.5V | 10±0.5V | 20±0.5V |
Over voltage protection | 15.5±0.5V | 31±0.5V | 15.5±0.5V | 31±0.5V |
Low voltage recover | 13±0.5V | 24±0.5V | 13±0.5V | 24±0.5V |
Over voltage recover | 14.8V±0.5V | 29.5V±0.5V | 14.8V±0.5V | 29.5V±0.5V |
Protection function | Low voltage | Alarm at first, voltage continously reduce. LED Red light on & shut sown. | ||
Over voltage | LED Red light on, shut down | |||
Over load | LED Red light on, shut down | |||
Over temperature | Alarm at first, tempurature continously rise.LED Red light on & shut sown | |||
Short circuit | LED Red light on | |||
Input reverse polarity | Fuse burn-out | |||
output current | 15A | 10A | 15A | 10A |
Constant current charging | 15A | 10A | 15A | 10A |
Constant voltage Charging | 14.6VDC | 28.8VDC | 14.6VDC | 28.8VDC |
Floating charge | 13.8VDC | 27.6VDC | 13.8VDC | 27.6VDC |
AC Input voltage Range | 190~260VAC | 90-135VAC | 190~260VAC | 90-135VAC |
Working temperature | -10°- +50° | |||
Storage temperature | -30°- +70° | |||
Note: Our products update constantly.The technical parameter is for reference only.Please refer to our real product. |